Rotary Viscometer Accessories
|
|
UL Adapter Kit
The UL Adapter allows measurement of viscosities down to 1 cP with the LV-2020 and 6.4 cP with the MV- 2020. Only 16 mL of sample are required for this accessory. The coaxial cylinder geometry of the unit provides well defined shear rates for detailed sample analysis. A water jacket enables temperature control of the sample. The UL Adapter Kit comes complete with sample chamber, spindle, water jacket, attachment hardware, and storage case.
- The UL Adapter permits reliable testing down to single-digit viscosities.
|
| |
|
Catalog #
|
Item Description
|
|
|
P17.1721
|
UL Adapter Kit |
 |
|
|
|
CANNON Small Sample Adapter Kit
The Small Sample Adapters permit testing of samples with volumes from 2 to 16 mL (the actual volume depends on the viscosity range of the sample and viscometer model in use). The coaxial cylinder geometry provides defined shear rates. A water jacket enables temperature control of the sample. The Small Sample Adapter Kit comes complete with one sample chamber and spindle, water jacket, attachment hardware, and storage case. Consult the Range Table for assistance in selecting the most appropriate Adapter model and spindle combination for your application.
|
|
Part #
|
Viscometer Type
|
|
|
|
|
|
|
P17.1710
|
LV
|
3-10K cP
|
8 mL
|
SC4-13R
|
SC4-18
|
 |
|
P17.1711
|
LV
|
30-100K cP
|
10.5 mL
|
SC4-13R
|
SC4-31
|
 |
|
P17.1712
|
LV
|
60-200K cP
|
11.5 mL
|
SC4-13R
|
SC4-34
|
 |
|
P17.1713
|
LV
|
120-400K cP
|
4.2 mL
|
SC4-8R
|
SC4-16
|
 |
|
P17.1714
|
LV
|
800-1.6M cP
|
16 mL
|
SC4-13R
|
SC4-25
|
 |
|
P17.1715
|
MV
|
50-170K cP
|
8 mL
|
SC4-13R
|
SC4-21
|
 |
|
P17.1716
|
MV
|
250-830K cP
|
10.5 mL
|
SC4-13R
|
SC4-27
|
 |
|
P17.1717
|
MV
|
500-1.7 M cP
|
3 mL
|
SC4-7R
|
SC4-15
|
 |
|
P17.1718
|
MV
|
500-1.7M cP
|
11.5 mL
|
SC4-13R
|
SC4-28
|
 |
|
P17.1719
|
MV
|
1M-3.3M cP
|
13 mL
|
SC4-13R
|
SC4-29
|
 |
|
P17.1720
|
MV
|
1.25M-4.2M cP
|
2 mL
|
SC4-6R
|
SC4-14
|
 |
|
|
|
Thermosel
The UL Adapter allows measurement of viscosities down to 1 cP with the LV-2020 and 6.4 cP with the MV- 2020. Only 16 mL of sample are required for this accessory. The coaxial cylinder geometry of the unit provides well defined shear rates for detailed sample analysis. A water jacket enables temperature control of the sample. The UL Adapter Kit comes complete with sample chamber, spindle, water jacket, attachment hardware, and storage case.
|
|
Catalog #
|
Item Description
|
|
|
P17.1704
|
Thermosel System, 115V |
 |
|
P17.1705
|
Thermosel System, 230V |
 |
|
|
|
SC4-31
|
SC4-34
|
SC4-21
|
SC4-27*
|
SC4-28
|
SC4-29
|
HT-DIN-8
|
|
|
8mL
|
10mL
|
95mL
|
8mL
|
10.5mL
|
11.5mL
|
13mL
|
13mL**
|
|
|
1.32N
|
.34N
|
.28N
|
.93N
|
.34N
|
.28N
|
.25N
|
.25N
|
|
|
3 - 101K
|
30 - 100K
|
60 - 200K
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
|
|
N/A
|
N/A
|
N/A
|
50 - 170K
|
250 - 830K
|
500 - 1.7M
|
1K - 3.3M
|
N/A
|
|
†Spindle SC4-18 1.32 x 10 (rpm) - 13.2 sec-1; N/A = Not applicable for historical reasons. However, it is possible to use any
spindle/chamber combination with any torque range. Digital viscometers/rheometers will atuomatically calculate viscostiy; *Optional
disposable SC4-27D spindle is available in quantities of 100, Part #SC4-27D-100. Requires special chuck/closer, Part #SC4-DSY, for
attachment to viscometer; **The 81 spindle, Part #HT-DIN-81, works in a HT-2 or HT-2DB chamber.
|
|