ACO-T602 Cleveland Open Cup Flash Point Tester

Model ACO-T602 automatically carries out Cleveland Open Cup (COC) flash point test of up to 6 samples in sequence. For high throughput labs, this carrousel model reduces the burden on the laboratory personnel.


Higher Lab Productivity:

Easy Programming: Up to 12 types of sample data can be stored and later recalled for quick and easy programming.

Electric Ignition: Reliable and easy-to-handle electric Ignitor is employed. Two pieces of coiled heater are placed near the sample cup rim. The ignitor has an extended period of life.

Innovative Flash Detector*: Ionization between the sample cup rim and either of the two electric igniters is detected as a flash occurs. The proven ionization method ensures highly reliable flash detection. Since the electric heater is self-cleaning, the need for messy cleaning of ionization detector is minimized.

Quick Cooling After Test: High velocity air cooling minimizes the waiting time between tests. The next test cycle is automatically initiated upon completion of the cooling cycle.

Auto Fire Containment: The ACO-T602 is equipped with a fire containment lid which closes automatically to prevent fire damage.

The programmable 6-position carrousel improves COC test throughput drastically.

Specifications

Conforming Standards:
ISO 2592, ASTM D92, IP 36, etc.

Measuring Range:
Ambient to 400 oC

Test Mode:
ASTM D92 Flash, Flash + Fire
Fire point must be visually monitored

Display:
Fluorescent display tube (VFD module)

Printer:
Thermal type printer (provided)

Temperature Sensor:
PT-100 in stainless steel sheath

Flash Detector:
Ionization between test cup and ignitors (patented)

Heater:
Nichrome Coil heater: 800W@100V or 800W@220V

Ignition Source:
Dual Electric Ignitors (platinum coil)

Cooling Device:
Forced air cooling by sirocco fan

Barometric Correction:
By entering the barometric pressure reading through the control
panel or fully automatic correction with an optional barometric
pressure sensor

Data Output:
RS-232C 1 channel

Safety Mechanism:
The instrument automatically shuts off and the problem is signaled by both buzzer and display.

Dimensions & Weight:
Control unit: 230W x 455D x 110H (mm), 6kg
Test unit: 405W x 515D x 400H (mm), 32kg
Printer: 134W x 180D x 58H (mm), 0.6kg

Installation Site:
Ambient temperature: 0 to 40oC
RH: Less than 90%(no condensation)

Power Supply:
AC100/120V or 220/240V 50/60Hz (set at the factory) 1.5kW(max.)

Standard Accessories:

    1 Test Cup 6pcs
    2 Tong 1pc
    3 Power Connecting Cable, 0.6m 1pc
    4 Signal Connecting Cable, 0.6m 1pc
    5 AC Power Cord, 1.5m 1pc
    6 Thermal Insulation (Heating Plate) 6pcs
    7 Printing paper 1pc
    8 Spare Electric Ignitor 2pcs
    9 Spare Insulating Collar for Ignitor 2pcs
    10 Spare Thermofuse 3pcs
    11 Instruction Manual 1 copy
    12 Insulation tube for Thermofuse, 0.1m 1 pc
    13 Printer, BS-80TSL with AC Adapter and Connecting Cable, 1.0m 1 set

Suggested Spares for 2 Years:

    1 Electric Ignitor 2pcs
    2 Insulating Collar for Ignitor 2pcs
    3 Thermofuse (pack of 5) 1pk
    4 Printing Paper 10pcs
    5 Temperature Sensor 1pc
    6 Nichrom Heater Coil 800W@100V or 800W@220V 1pc